I100-S-WI

| Compact Units R100 |

  • I100-S-WI

    Cost-effective Double Sheet Detection with single probe sensor.

  • Single probe sensor, inductive
  • Single probe measurement at a single sheet metal thickness of:
    - Tinplate 0.15 ... 0.25mm (0.4mm, depending on alloy) 
    - Aluminum 0.05 ... 0.40mm
    - Non-magnetic stainless steel 0.50 ... 3mm 
  • Easy set-up by key operation or via control input
  • LCD display for visualization of - nominal / current values - operational / error messages - key allocation
  • Compact enclosure, aluminum, protection class IP54
    Technology: Inductive
    Sensor: WI42GS
    Meas. range:
    Steel magn. [FE] 0.15 ... 0.25mm (0.4mm, depending on alloy)
    Aluminum [NF] 0.05 ... 0.40mm
    Stainl. steel aust aust.[NF] 0.5 ... 3mm
    Non-metals --
    Air gape: Maximum 2 mm
    Particularity: Up to 2 mm distance to sheet possible
    Meas. time: 30ms
    Applications: Cost-effective Double Sheet Detection with single probe sensor
    Material + Thickness:

    Measurement of

    - Tinplate 0.15 ... 0.25mm (0.4mm, depending
       on alloy)
    - Aluminium 0.05 ... 0.40mm
    - Non-magnetic Stainless Steel 0.5 ... 3mm

    Meas. method: Single probe Double Sheet Detector
    Functional principle: Single probe Sensor, inductive
    Programs: 1 measurement program, memory storage
    Switching threshold: 85% and 115% of nominal value